Page 18
OFF
3rd
SPEED
d. START/AUX Function
After initiating the START function the Start position will become an auxiliary function with
momentary contact. For auxiliary application such as horn or buzzer, please connect it to the
FUNC output relay (wire #6) located inside the receiver unit.
e. Magnet ON/OFF Push Button Function
The user can set any of the two adjacent push buttons on the transmitter to control a magnet. To
activate the magnet just press the push button with the Magnet symbol. To deactivate the magnet,
for safety purpose, you must first press and hold the Magnet push button and then press the OFF
push button. Press the OFF push button by itself can not deactivate the magnet (refer to page 20
on how to set to this function).
f. Brake Function
When the transmitter push button is released from 2
nd
speed up to 1
st
speed, both 1
st
and 2
nd
speed output relays will open for up to 1.0 second and then with 1
st
speed output relay closed
thereafter (refer to page 20 on how to set to this function).
g. Momentary Contact
When push button is released the output relay corresponds to that push button will open (refer to
page 21 on how to set to this function). This type of contact is usually applies to external
application such as horns or buzzers.
h. Toggled Contact
When push button is released the output relay corresponds to that push button will remained
closed (maintained contact) until next time the user presses the same push button again (refer to
page 21 on how to set to this function). This type of contact is usually applies to external
application such as lights.
i. 3
rd
Speed Push Button Function
This function allows the crane to travel an additional step beyond 2
nd
speed. For example, if the
operator is pressing the “UP” push button down to 2
nd
speed, pressing the 3
rd
speed push button
(with “UP” push button still hold at 2
nd
speed) will toggle between 2
nd
speed and 3
rd
speed (refer
to page 21 on how to set to this function).