Page 21
b. Non-Interlocked Functions
Contrary to interlocked settings, non-interlocked settings allow the two adjacent push buttons
be used simultaneously at the same time. Non-interlocked settings are usually applied to
crane’s auxiliary functions such as lights, horn, 3
rd
speed, auxiliary stop and Pitch & Catch.
Each dip-switch on the decoder module corresponds to one (1) motion or two (2) adjacent
push buttons (left & right push buttons).
Function
Code
Dip
Position
Setting
#1
Dip Position Setting
#2 ~ #4 (left button)
&
#5 ~ #7 (right button)
Function Description
A 1 000
Normal (momentary) contact.
B 1 001
Toggled (latching) contact.
C 1 010
Acceleration (3
rd
speed).
D 1 011
Toggled (latching) contact affected by the
E-Stop command. When E-Stop command
is initiated, all toggled (latching) relays are
also deactivated.
E 1 101
Pitch & Catch Type-1. When Pitch (release)
function is initiated, receiver MAIN will
not be deactivated.
F 1 110
Pitch & Catch Type-2. When Pitch (release)
function is initiated, receiver MAIN will
be deactivated.
G 1 111
Auxiliary Stop.
Example #1: Left button (set to function code A) / right button (set to function code A) → 1 000 000
Example #2: Left button (set to function code B) / right button (set to function code B) → 1 001 001
Example #3: Left button (set to function code A) / right button (set to function code C) → 1 000 010
Example #4: Left button (set to function code F) / right button (set to function code A) → 1 110 000
! When set to Pitch & Catch function make sure the 2
nd
transmitter is set to the next upper channel. For example, if the
system is preset at Ch.01 then the 2
nd
transmitter should be set to Ch.02. Furthermore, you must also set the dip-switch
on the receiving module (position #7 & #8) to “01” position (2-channel scanning), please refer to page 19.