6. RECEIVER INSTALLATION
6.1 OUTPUT RELAY CONTACT DIAGRAM
* For 3-relay (shared 2
nd
speed) and 4-relay (separate 2
nd
speed) configuration please refer to page
30.
* For 4-relay closed/closed and 4-relay opened/closed relay configuration please refer to pages 30
and 31.
* For different voltage settings please refer to page 37.
* For F9 and F10 power fuse ratings please refer to page 37.
* For 12 - 24VDC power supply, wire #1 corresponds to the negative charge (-) and wire #3
corresponds to the positive charge (+). Wire #2 is for GROUND.