Flex PRO / Flex M Pre-Engineered Radio Control System Instruction Manual
April 2012
Page 17 of 42
4.2. INACTIVITY TIME OUT TIMER
Bits 6 and 7 on the dip-switch allows the user to define a time after which, if no buttons on the transmitter
are pressed, the Flex Pro will send an OFF command to the receiver and power down. To restart, the
user must turn the On/Off/Start switch to the Off position, then back to On again to resume operation.
Figure 9
4.3. A/B/BOTH SELECT
Bit 8 on the dip-switch allows the user to set the lower left pushbutton (PB7 on the Flex 8 PRO, PB11 on
the Flex 12 PRO) into an A / B / BOTH Select button. When the A / B / BOTH Select button is enabled, it
can be used to toggle through the desired outputs as follows: A > B > BOTH > A ...
Figure 10
NOTE: When A/B Select function is Enabled, A/B LEDs will be OFF at initial startup, but will remain ON
(A, B, or BOTH) once selected. When A/B Select function is disabled, A/B LEDs will remain OFF.
Time Out
Dip-switch
Setting
5 minutes 01
10 minutes 10
15 minutes
11
Never shut off 00
A / B / BOTH
Dip-switch
Setting
Enabled 1
Disabled
0