Magnetek Flex 12RS System Manual de instrucciones Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 42
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
Flex PRO / Flex M Pre-Engineered Radio Control System Instruction Manual
April 2012
Page 28 of 42
9.2. FLEX M POWER SUPPLY MODULE
The Flex M Power Supply Module converts the supply power to 5VDC power for all the attached Flex M
modules. This power module has a maximum output supply current of 1000mA. There is one Power
Supply Module in the Flex M system.
Figure 22: Power Supply Module Detail View
Figure 23: Typical 120VAC Power Wiring Figure 24: Typical VDC Power Wiring
NOTES:
1. Although the power module has built-in protection, Magnetek strongly recommends the use of
external fuses and circuit disconnects for all Flex modules.
2. The built-in fuse is not user serviceable but can be checked if troubleshooting. To check the
fuse, remove the power module from the din rail as described in Section 7.2. After removing the
module from the din rail, press in the tabs as noted above to remove the PCB from the housing.
The fuse is location is shown in the PCB view above. Use a multimeter to check for continuity
across the fuse. If the fuse is blown, contact Magnetek to send the module in for service.
3. The total system Current Consumption should not exceed the Maximum Output Supply Current of
the power supply module. If additional supply current is required, contact the factory for a custom
solution.
Not Used
Not Used
Not Used
GND
(+) VDC
(-) COM
(+) VDC
(-) COM
120VAC (L)
120VAC (N)
120VAC (L)
120VAC (N)
Not Used
Not Used
Not Used
GND
Vista de pagina 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 41 42