Magnetek Flex 12RS System Manual de instrucciones Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 42
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
Flex 4EX System Instruction Manual
December 2012
22 of 39
F1 R1 F2 R2R2F2R1F1
R2F2R1F1 R2F2R1F1
ON
OFF
4-output relays configuration with Opened/Closed contact at 2
nd
speed
At 2
nd
speed, only the 2
nd
speed (F2 or R2) output relay is closed (refer to page 25
on how to set to this function).
Forward 1
st
speed push button pressed Forward 2
nd
speed push button pressed
4-output relays configuration with Closed/Closed contact at 2
nd
speed
At 2
nd
speed, both 1
st
speed (F1 or R1) and 2
nd
speed (F2 or R2) output relays are
closed (refer to page 25 on how to set to this function).
Forward 1
st
speed push button pressed Forward 2
nd
speed push button pressed
4.2.2.3 ON/OFF Push Button Function
The user can set any of the two adjacent push buttons on the transmitter to behave like a
mechanical ON & OFF rocker switch (refer to page 25 on how to set to this function).
When the “On” output relay is closed (“On” push button pressed), the “Off” output relay
will open automatically, or vice versa.
4.2.2.4 START/AUX Function
After initiating the START function the Start position will become an auxiliary function with
momentary contact. For auxiliary applications such as horns or buzzers, please connect it
to the FUNC output relay (wire #5) located inside the receiver unit.