4.2.4.2 Non-Interlocked Functions
Contrary to interlocked settings, non-interlocked settings allow the two adjacent push
buttons be used simultaneously. Non-interlocked settings are usually applied to a crane’s
auxiliary functions, such as lights, a horn, 3
rd
speed and auxiliary stop. Each dip-switch
on the decoder module corresponds to one (1) motion or two (2) adjacent push buttons
(left & right push buttons).
Function
Code
Dip
Position
Setting
#1
Dip Position Setting
#2 - #4 (left button)
&
#5 - #7 (right button)
Function Description
A 1 000 Normal (momentary) contact.
B 1 001 Toggled (latching) contact.
C 1 010 Acceleration (3
rd
speed).
D 1 011
Toggled (latching) contact affected by the
E-Stop command. When the E-Stop
command is initiated, all toggled (latching)
relays are also deactivated.
E 1 111 Auxiliary Stop.
F 1 100
Normal + Start function. For added safety,
you must first rotate and hold the power key
switch at “START” position and then press
the intended push button at the same
time to activate the output relay.
Example #1: Left button (set to function code A) / right button (set to function code A) → 1 000 000
Example #2: Left button (set to function code B) / right button (set to function code B) → 1 001 001
Example #3: Left button (set to function code A) / right button (set to function code C) → 1 000 010
Example #4: Left button (set to function code D) / right button (set to function code E) → 1 011 111