Enrange MHR Instruction Manual
August 2014
Page 32 of 57
The following setting options are used to configure the selected output for the application being
used and can be accessed through the individual output menus for each output number.
NOTE: The following setting options have no effect when the output Config Type is set to Digital
Output or Digital Input.
• Minimum Current (Only used for Current Comp)
• Sets the minimum output current for the selected output number.
• The range is 100 to 3000mA.
• Maximum Current (Only used for Current Comp)
• Sets the maximum output current for the selected output number.
• The range is 100 to 3000mA
• Start Ramp (Only applies to Open Loop and Current Comp)
• Sets the ramp up time for the start of the output signal being sent.
• The range is 0 to 1000ms
• Stop Ramp (Only applies to Open Loop and Current Comp)
• Sets the ramp down time for the output signal being sent
• The range is 0 to 1000ms
• Min Duty Cycle (Only used for Open Loop PWM)
• Sets the minimum duty cycle percentage
• The range is 0 to 100%
• Max Duty Cycle (Only used for Open Loop PWM)
• Sets the maximum duty cycle percentage
• The range is 0 to 100%
To adjust any of the output configuration setting, select the desired output number and press the
button to access the configuration menu options for the specific output number selected.
Use the
and buttons to scroll through the menu options (Maximum Current, Minimum
Current, etc.). Press the
button to enter the screen that adjusts the selected setting in the
menu option. Use the
and buttons to cycle through each digit and use the and
buttons to change the values of the digit selected.
After the last digit is entered on the far right side of the PWM Frequency screen, press
to
return to the selected output configuration menu.
To exit back to the main menu screen press the
button.