Alarm
Number
Alarm
Text
Cause of alarm Effect of alarm Recovery Action
50
S50. OUT
3 -VB
SHORT
When the output is
supposed to be at
+VBat, a voltage of
2V or less was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system
51
S51. OUT
4 -VB
SHORT
When the output is
supposed to be at
+VBat, a voltage of
2V or less was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system
52
S52. OUT
5 -VB
SHORT
When the output is
supposed to be at
+VBat, a voltage of
2V or less was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system
53
S53. OUT
6 -VB
SHORT
When the output is
supposed to be at
+VBat, a voltage of
2V or less was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system
54
S54. OUT
7 -VB
SHORT
When the output is
supposed to be at
+VBat, a voltage of
2V or less was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system
55
S55. OUT
8 -VB
SHORT
When the output is
supposed to be at
+VBat, a voltage of
2V or less was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system